Details
Different cartridge kits are available for usage with Qsep1 and Qsep100 Biofragment-Analyzers
- For the anaylsis of DNA or RNA or Proteins
- Standard Cartridges, Fast-Cartdriges, Quantification
- High-Resolution Cartridges and High-Sensitivity Cartridges
The tables and overviews shown at the following table or tabs (Applications and Specifications) can help to select the best cartridge for your needs.
Availability
The Qsep Fragment Analyzers and Cartridges are available in Germany, Austria, Belgium, Denmark, Finnland, Greece, Croatia and Serbia. For other countries, please contact us.
Specifications
DNA Cartridges
|
Standard Cartridge (S2) |
High Resolution Cartridge (S1) |
Fast Cartridge (F3)
Only suitable for Qsep100 |
High Sensitivity Cartridge (N1) |
Kilo Base Cartridge (S3) |
High Sensitivity Kilo Base Cartridge (N3) |
Quantitative Standard Cartridge (S2) |
Quantitative High Resolution Cartridge (S1) |
Cat. No. |
C105201 (2 pcs) |
C105202 (2 pcs) |
C105203 (2 pcs) |
C105105 (1 pc) |
C105206 (2 pcs) |
C105153 (1 pc) |
C105201-Q (2 pcs) |
C105202-Q (2 pcs) |
|
C105801 (8 pcs) |
C105802 (8 pcs) |
C105803 (8 pcs) |
C105205 (2 pcs) |
C105806 (8 pcs) |
C105253 (2 pcs) |
|
|
Sample size range |
10-5000 bp |
10-5000 bp |
10-5000 bp |
10-5000 bp |
10-50000 bp |
10-50000 bp |
10-5000 bp |
10-1500 bp |
L.O.D. |
0.1 ng/µL* |
0.1 ng/µL* |
0.1 ng/µL* |
5 pg/µL* |
0.1 ng/µL* |
5 pg/µL* |
0.1 ng/µL* |
0.1 ng/µL* |
Best Resolution |
4-10 bp |
1-4 bp |
>50 bp |
>10 bp |
10-50 bp |
10-50 bp |
4-10 bp |
1-4 bp |
Analysis time (per sample) |
2-3 mins |
3-5 mins |
1-2 mins |
2-3 mins |
5-21 mins |
9-25 mins |
2-3 mins |
3-5 mins |
Sample number (per cartridge) |
200 runs |
200 runs |
300 runs |
100 runs |
200 runs |
100 runs |
200 runs |
200 runs |
Sample consumption (per run) |
<0.1 µL |
<0.1 µL |
<0.1 µL |
<0.1 µL |
<0.1 µL |
<0.1 µL |
<0.1 µL |
<0.1 µL |
Recommended sample volume |
0.1 mL tube:
10 µL |
0.1 mL tube:
10 µL |
0.1 mL tube:
10 µL |
0.1 mL tube:
10 µL |
0.1 mL tube:
10 µL |
0.1 mL tube:
10 µL |
0.1 mL tube:
10 µL |
0.1 mL tube:
10 µL |
|
0.2 mL tube:
20 µL |
0.2 mL tube:
20 µL |
0.2 mL tube:
20 µL |
0.2 mL tube:
20 µL |
0.2 mL tube:
20 µL |
0.2 mL tube:
20 µL |
0.2 mL tube:
20 µL |
0.2 mL tube:
20 µL |
|
Micro vial:
2 µL (C104250) |
Micro vial:
2 µL (C104250) |
Micro vial:
2 µL (C104250) |
|
Micro vial:
2 µL (C104250) |
Micro vial:
2 µL (C104250) |
|
|
Shelf life |
6 months |
6 months |
4 months |
3 months |
6 months |
3 months |
6 months |
6 months |
* Determined by the DNA ladder 15-622 (DNA size marker C109200)
L.O.D.: 2pg/µL (if diluted in water)
RNA and Protein Cartridges
|
RNA Cartridge (R1) |
High Sensitivity RNA Cartridge (NR1) |
Protein Cartridge (SDS) (P2) |
Cat. No. |
C105110 (1 pc) |
C105111 (1 pc) |
C105121 (1 pc) |
|
C105210 (2 pcs) |
C105211 (2 pcs) |
C105221 (2 pcs) |
|
C105810 (8 pcs) |
|
|
Sample size range |
N/A |
N/A |
14-150 kDa |
L.O.D. |
5 ng/µL |
1 ng/µL |
0.5 ng/µL (BSA) |
Best Resolution |
N/A |
N/A |
N/A |
Analysis time (per sample) |
5-10 mins |
5-10 mins |
6 mins (BSA) |
|
|
|
10 mins (IgG) |
Sample number (per cartridge) |
100 runs |
100 runs |
100 runs |
Sample consumption (per run) |
<0.1 µL |
<<0.1 µL |
<0.1 µL |
Recommended sample volume |
0.1 mL tube: 10 µL |
0.1 mL tube: 10 µL |
0.1 mL tube: 10 µL |
|
0.2 mL tube: 20 µL |
0.2 mL tube: 20 µL |
0.2 mL tube: 20 µL |
|
Micro vial: 2 µL |
Micro vial: 2 µL |
|
|
(C104250) |
(C104250) |
|
Shelf life |
3 months |
3 months |
3 months |
L.O.D.: 2pg/µL (if diluted in water)