Different cartridge kits are available for usage with Qsep400 Bio-Fragment-Analyzer
- For the anaylsis of DNA or RNA or Proteins
- Standard Cartridges, Fast-Cartdriges, Quantification
- High-Resolution Cartridges and High-Sensitivity Cartridges
The tables and overviews shown at the following tabs can help to select the best cartridge for your needs.
Availability
The Qsep Fragment Analyzers and Cartridges are available in Germany, Austria, Belgium, Denmark, Finnland, Greece, Croatia and Serbia. For other countries, please contact us.
Specifications
DNA Cartridges
|
Standard Cartridge (S2) |
High Resolution Cartridge (S1) |
Fast Cartridge (F3) |
High Sensitivity Cartridge (N1) |
Kilo Base Cartridge (S3) |
Quantitative Standard Cartridge (S2) |
Quantitative High Resolution Cartridge (S1) |
Cat. No. |
C405101 (1 pc) |
C405102 (1 pc) |
C405103 (1 pc) |
C405105 (1 pc) |
C405106 (1 pc) |
C405101-Q (1 pc) |
C405102-Q (1 pc) |
Sample size range |
10-5000 bp |
10-5000 bp |
10-5000 bp |
10-5000 bp |
10-50000 bp |
10-1500 bp |
10-1500 bp |
L.O.D. |
0.1 ng/µL* |
0.1 ng/µL* |
0.1 ng/µL* |
5 pg/µL* |
0.1 ng/µL* |
0.1 ng/µL* |
0.1 ng/µL* |
Best Resolution |
4-10 bp |
1-4 bp |
>50 bp |
>10 bp |
10-50 bp |
4-10 bp |
1-4 bp |
Analysis time (per 4 samples) |
2-3 min |
3-5 min |
1-2 min |
2-3 min |
5-21 min |
2-3 min |
3-5 min |
Sample number (per cartridge) |
800 runs |
800 runs |
1200 runs |
400 runs |
800 runs |
800 runs |
800 runs |
Sample consumption (per run) |
<0.1 µL |
<0.1 µL |
<0.1 µL |
<0.1 µL |
<0.1 µL |
<0.1 µL |
<0.1 µL |
Recommended sample volume |
0.1 mL tube:
10 µL |
0.1 mL tube:
10 µL |
0.1 mL tube:
10 µL |
0.1 mL tube:
10 µL |
0.1 mL tube:
10 µL |
0.1 mL tube:
10 µL |
0.1 mL tube:
10 µL |
|
0.2 mL tube:
20 µL |
0.2 mL tube:
20 µL |
0.2 mL tube:
20 µL |
0.2 mL tube:
20 µL |
0.2 mL tube:
20 µL |
0.2 mL tube:
20 µL |
0.2 mL tube:
20 µL |
|
Micro vial:
2 µL (C104250) |
Micro vial:
2 µL (C104250) |
Micro vial:
2 µL (C104250) |
|
Micro vial:
2 µL (C104250) |
|
|
Shelf life |
6 months |
6 months |
4 months |
3 months |
6 months |
6 months |
6 months |
* Determined by the DNA ladder 15-622 (DNA size marker C109200)
L.O.D.: 2pg/µL (if diluted in water)
RNA- and Protein Cartridges
|
RNA Cartridge (R1) |
Protein Cartridge (SDS) (P2) |
Cat. No. |
C405110 (1 pc) |
C405121 (1 pc) |
Sample size range |
N/A |
14-150 kDa |
L.O.D. |
5 ng/µL |
0.5 ng/µL (BSA) |
Best Resolution |
N/A |
N/A |
Analysis time (per 4 samples) |
5-10 min |
6 min (BSA) |
|
|
10 min (IgG) |
Sample number (per cartridge) |
400 runs |
400 runs |
Sample consumption (per run) |
<0.1 µL |
<0.1 µL |
Recommended sample volume |
0.1 mL tube: 10 µL |
0.1 mL tube: 10 µL |
|
0.2 mL tube: 20 µL |
0.2 mL tube: 20 µL |
|
Micro vial: 2 µL |
|
|
(C104250) |
|
Shelf life |
3 months |
3 months |
L.O.D.: 2pg/µL (if diluted in water)